Smoke alarms and rental electrical safety checks
Victorian smoke alarm requirements by build date, hardwired and interconnected alarms, and the two-yearly electrical safety check for Berwick rentals.
The smoke alarms a Victorian home must have depend on when it was built or significantly renovated, and rental homes carry extra checks on top. Fire Rescue Victoria’s published guidance sets the minimum: homes built before 1 August 1997 can use any smoke alarm, including a 9-volt battery type; homes built after that date need hardwired alarms on mains power with a battery backup; and homes built after 1 May 2014 need those hardwired alarms interconnected. Any hardwired work must be done by a licensed electrician.

Bookings for alarms or safety checks are made directly with the independent licensed electrician who responds, not with this site.
Minimum smoke alarm requirements by build date
| Built or significantly renovated | Minimum requirement | Who can install |
|---|---|---|
| Before 1 August 1997 | Any smoke alarm, including replaceable 9-volt battery types | Anyone for battery alarms |
| After 1 August 1997 | Hardwired to 240 volt mains with a backup battery | Licensed electrician |
| After 1 May 2014 | Hardwired, mains powered with battery backup, and interconnected | Licensed electrician |
This table follows the Fire Rescue Victoria smoke alarm brochure (May 2026). The same brochure says alarms must be installed between every sleeping area and the rest of the home, each level must have at least one, all alarms must meet AS 3786, and every alarm, hardwired units included, should be replaced every 10 years. When you replace alarms you must keep at least the minimum standard for your home; extra alarms beyond the minimum do not have to meet it.
Should you go beyond the minimum?
Fire Rescue Victoria recommends interconnected alarms in every bedroom and living area, because research it cites found that a fire starting in a bedroom with the door closed may not set off the alarm in the hallway. Interconnection means that when one alarm detects smoke, all of them sound.
| Option | Good for | Published range |
|---|---|---|
| Hardwired alarm, supplied and installed | Replacing old hardwired units, renovations, new rooms | $105 to $260 per alarm |
| Hardwired alarm fitted by an electrician, fire services estimate | Same work, indicative figure from FRV | $160 to $350 per alarm |
| Wireless interconnected alarms with 10-year batteries | Adding bedroom alarms to an older home in stages | Priced per alarm; installation is not licensed electrical work |
The first range comes from a published Melbourne electrician cost guide, GST included. The second is Fire Rescue Victoria’s own indicative figure, which it says varies with wiring and access. More detail is on the Berwick cost guide.
Rental electrical safety checks
Consumer Affairs Victoria says rental providers must have the electrical installation, fixtures and fittings checked by a licensed or registered electrician every two years. Energy Safe Victoria’s residential tenancy guidance adds that the check follows the periodic assessment standard AS/NZS 3019 and covers all switchboards, wiring and fittings, under the Residential Tenancies Regulations 2021, for agreements entered into after 29 March 2021.
Points a rental provider or property manager should know, from the Consumer Affairs Victoria rental safety page:
- Before a renter signs, the provider must disclose the date of the last electrical safety check and any outstanding recommendations.
- If no check has been done in the last two years when a renter moves in, it should be done as soon as possible.
- The provider must keep a record of the most recent check and give the renter a copy within 7 days of a written request.
For smoke alarms in rentals, Consumer Affairs Victoria’s smoke alarm page says the provider must make sure every alarm is correctly installed and working, fitted with batteries, and tested at least once every 12 months following the manufacturer’s instructions, and that annual smoke alarm safety checks became mandatory for all rental properties from 25 November 2025. Consumer Affairs also says that since 29 March 2023 every power outlet and lighting circuit in a rental must be on a switchboard-type circuit breaker and safety switch, so a check on an older rental can lead to switchboard and safety switch work.
What a provider will check or need
- The build year or date of any major renovation, so they know which minimum applies.
- How many bedrooms, levels and living areas there are.
- Whether existing alarms are hardwired, and how old they are (the date is usually on the back).
- For a rental check: access to the switchboard and every room, and the previous check report if there is one.
- For a property manager: renter contact details and access times.
What the work involves
For alarm replacement, the electrician isolates the circuit, swaps each unit for a compatible model, interconnects where required, and tests every alarm. A safety check involves visual inspection and testing of the switchboard, wiring and fittings, a report listing anything that needs fixing, and a separate quote for repairs. Repair work is then certified like any other job.
What a careful provider will not do
- Replace a hardwired alarm in a post-1997 home with a battery-only unit as the required alarm.
- Sign off a rental check without testing the safety switches.
- Mix alarm brands that cannot interconnect where interconnection is required.
- Treat a rental check report as a repair. The report and the repairs are separate.
Berwick rentals and older homes
In the 2021 Census, 22.0 per cent of Berwick’s occupied private dwellings were rented, and the figure was 28.4 per cent in neighbouring Narre Warren. For an older rental the legal minimum may only be battery alarms, but booking the alarm work on the same visit as the two-yearly electrical check saves a second trip. Homes in newer estates such as those in Officer may already have interconnected alarms that are approaching their 10-year replacement.
What to do next
Gather the build year, the number of bedrooms and levels, and the last check report if it is a rental. Then book in an enquiry for alarms or a safety check and say whether you are an owner-occupier, rental provider or property manager.
Frequently asked questions
- Do I have to replace battery smoke alarms with hardwired ones?
It depends on when the home was built. Fire Rescue Victoria says pre-August 1997 homes may use any compliant alarm, while later homes need hardwired alarms and post-May 2014 homes need them interconnected.
- How often should smoke alarms be replaced?
Fire Rescue Victoria advises replacing every smoke alarm, hardwired ones included, every 10 years. The manufacture date is usually printed on the unit.
- How often does a rental need an electrical safety check?
Every two years, by a licensed or registered electrician. Rental providers must tell a new renter when the last check was done and keep a record of the latest one.
- Who pays for repairs found during a rental check?
Repairs are quoted separately from the check. Responsibility between rental provider and renter follows the rental agreement and Consumer Affairs Victoria rules.
- Can anyone install wireless interconnected alarms?
Battery-powered wireless alarms do not need an electrician. Any alarm wired into mains power must be installed by a licensed electrician.